Designed to simulate ventricular action of heart for testing heart valve designs, Pulsatile Blood Pumps are available in 4 models ranging from Mouse/Rat version, which can circulate up to 200 mL/min, to Large Animal model, which circulates up to 10 L/m and can simulate human capability. Controlled via 0-10 Vdc signal, pumps can interface with computer to generate advanced cardiovascular waveforms and control pressure curves.

********************

Harvard Apparatus now offers Pulsatile Blood Pump models with an autoclavable pumping head, to better maintain sterility, as well as external voltage control models to make the testing of various heart valve and designs much easier.

Features include:

o Simulates ventricular action of the heart

o New autoclavable pumping head

o External control interfaces the blood pump with a computer to generate advanced cardiovascular waveforms and more control over pressure curves

o 4 Models for research from mice/rats up to large animals

Harvard Apparatus has been producing blood pumps for the past 50 years. The design has a proven track record for reproducing all aspects of the ventricular action of the heart for a wide range of animals while minimizing hemolysis.

Harvard Apparatus offers 4 separate versions from the Mouse/Rat model which can circulate up to 200 milliliters per minute, to the Large Animal model, which can circulate up to 10 liters per minute (used to simulate human capability).

The Pulsatile now offers the pumping head in polysulfone which is autoclavable. The standard models use acrylic which must be sterilized using ethylene oxide or other methods. This new material makes it much easier to maintain sterility.

Also offered is a new control method for the blood pumps. Normally the pump is controlled through a set of potentiometers; one controls stroke rate and the other controls the phasing between systole/diastole.

Now the pump can be controlled from an external voltage source; 0 to 10 volt DC signal can be used to control the stroke rate and phasing of the pump. External control interfaces the blood pump with a computer to generate advanced cardiovascular waveforms and more control over pressure curves.

A computer could generate a particular cardiovascular profile and the pump would create that blood flow profile. Any abnormal heart rhythms or defects could be simulated at the blood pump. This will make testing various heart valves and designs much easier.

This new DC control feature will work with data acquisition systems, controlling blood flow based on feedback from sensors. The new DC control version would have a selector switch, which would allow the user to select either internal or external control.

For more information about the Harvard Apparatus Pulsatile Blood Pumps please contact the technical support department.

Harvard Apparatus is a global developer, manufacturer and distributor of innovative and specialized products to enhance bioresearch.

Source Citation
"Pulsatile Blood Pumps feature autoclavable pumping head." Product News Network 29 Sept. 2011. Gale Power Search. Web. 13 Feb. 2012.
Document URL
http://go.galegroup.com/ps/i.do?id=GALE%7CA268292490&v=2.1&u=22054_acld&it=r&p=GPS&sw=w

Gale Document Number: GALE|A268292490

ArabicChinese (Simplified)Chinese (Traditional)DeutchEspanolFrenchItalianJapaneseKoreanPortugueseRussian

Designed to simulate ventricular action of heart for testing heart valve designs, Pulsatile Blood Pumps are available in 4 models ranging from Mouse/Rat version, which can circulate up to 200 mL/min, to Large Animal model, which circulates up to 10 L/m and can simulate human capability. Controlled via 0-10 Vdc signal, pumps can interface with computer to generate advanced cardiovascular waveforms and control pressure curves.

********************

Harvard Apparatus now offers Pulsatile Blood Pump models with an autoclavable pumping head, to better maintain sterility, as well as external voltage control models to make the testing of various heart valve and designs much easier.

Features include:

o Simulates ventricular action of the heart

o New autoclavable pumping head

o External control interfaces the blood pump with a computer to generate advanced cardiovascular waveforms and more control over pressure curves

o 4 Models for research from mice/rats up to large animals

Harvard Apparatus has been producing blood pumps for the past 50 years. The design has a proven track record for reproducing all aspects of the ventricular action of the heart for a wide range of animals while minimizing hemolysis.

Harvard Apparatus offers 4 separate versions from the Mouse/Rat model which can circulate up to 200 milliliters per minute, to the Large Animal model, which can circulate up to 10 liters per minute (used to simulate human capability).

The Pulsatile now offers the pumping head in polysulfone which is autoclavable. The standard models use acrylic which must be sterilized using ethylene oxide or other methods. This new material makes it much easier to maintain sterility.

Also offered is a new control method for the blood pumps. Normally the pump is controlled through a set of potentiometers; one controls stroke rate and the other controls the phasing between systole/diastole.

Now the pump can be controlled from an external voltage source; 0 to 10 volt DC signal can be used to control the stroke rate and phasing of the pump. External control interfaces the blood pump with a computer to generate advanced cardiovascular waveforms and more control over pressure curves.

A computer could generate a particular cardiovascular profile and the pump would create that blood flow profile. Any abnormal heart rhythms or defects could be simulated at the blood pump. This will make testing various heart valves and designs much easier.

This new DC control feature will work with data acquisition systems, controlling blood flow based on feedback from sensors. The new DC control version would have a selector switch, which would allow the user to select either internal or external control.

For more information about the Harvard Apparatus Pulsatile Blood Pumps please contact the technical support department.

Harvard Apparatus is a global developer, manufacturer and distributor of innovative and specialized products to enhance bioresearch.

Source Citation
"Pulsatile Blood Pumps feature autoclavable pumping head." Product News Network 29 Sept. 2011. Gale Power Search. Web. 13 Feb. 2012.
Document URL
http://go.galegroup.com/ps/i.do?id=GALE%7CA268292490&v=2.1&u=22054_acld&it=r&p=GPS&sw=w

Gale Document Number: GALE|A268292490

Personalized MY M&M'S® Candies
ArabicChinese (Simplified)Chinese (Traditional)DeutchEspanolFrenchItalianJapaneseKoreanPortugueseRussian
(Web-Page) http://dinosaur.hunter2008.googlepages.comHoliday 2008
Lowest Prices and Hassle Free Returns at WWBW.com(Album / Profile) http://www.facebook.com/album.php?aid=10031&id=1661531726&l=cf90f7df9cShop the Official Coca-Cola Store!Email: leonard.wilson2009@hotmail.comWal-Mart.com USA, LLC

No comments: